Hanna (HI7010-M) Ph 10.01 Buffer Caliberation Solution; 230ML
Technical Details
| Model Number | HI7010-M |
| pH Value | 10.01 at 25°C |
| Volume | 230mL |
| Accuracy | ±0.01 pH at 25°C |
| Traceability | NIST SRM Certified |
| Manufacturing Standard | ISO 3696/BS3978 |
| Production Environment | Temperature Controlled |
| Compatible With | All Hanna pH Meters |
Calibration Procedure
- Remove protective cap from pH electrode and rinse probe with deionized or distilled water
- Pour fresh HI7010-M buffer solution into a clean beaker and immerse electrode, ensuring junction and bulb are fully submerged
- Follow your Hanna meter's calibration protocol to set the 10.01 pH point, allowing readings to stabilize before confirming
- Rinse electrode thoroughly with deionized water after calibration and store according to manufacturer instructions
- Discard used buffer solution after each calibration session to maintain accuracy
Works With
The HI7010-M pH 10.01 buffer solution is compatible with all Hanna Instruments pH meters and electrodes, as well as most third-party pH testing equipment requiring alkaline calibration points. Use this buffer as part of a two-point or three-point calibration alongside pH 4.01 and pH 7.01 buffers for complete range accuracy in water quality testing, aquarium monitoring, hydroponics, and reverse osmosis system management.
Technical Details
| Model Number | HI7010-M |
| pH Value | 10.01 at 25°C |
| Volume | 230mL |
| Accuracy | ±0.01 pH at 25°C |
| Traceability | NIST SRM Certified |
| Manufacturing Standard | ISO 3696/BS3978 |
| Production Environment | Temperature Controlled |
| Compatible With | All Hanna pH Meters |
Calibration Procedure
- Remove protective cap from pH electrode and rinse probe with deionized or distilled water
- Pour fresh HI7010-M buffer solution into a clean beaker and immerse electrode, ensuring junction and bulb are fully submerged
- Follow your Hanna meter's calibration protocol to set the 10.01 pH point, allowing readings to stabilize before confirming
- Rinse electrode thoroughly with deionized water after calibration and store according to manufacturer instructions
- Discard used buffer solution after each calibration session to maintain accuracy
Works With
The HI7010-M pH 10.01 buffer solution is compatible with all Hanna Instruments pH meters and electrodes, as well as most third-party pH testing equipment requiring alkaline calibration points. Use this buffer as part of a two-point or three-point calibration alongside pH 4.01 and pH 7.01 buffers for complete range accuracy in water quality testing, aquarium monitoring, hydroponics, and reverse osmosis system management.
Original: $32.00
-65%$32.00
$11.20Description
Technical Details
| Model Number | HI7010-M |
| pH Value | 10.01 at 25°C |
| Volume | 230mL |
| Accuracy | ±0.01 pH at 25°C |
| Traceability | NIST SRM Certified |
| Manufacturing Standard | ISO 3696/BS3978 |
| Production Environment | Temperature Controlled |
| Compatible With | All Hanna pH Meters |
Calibration Procedure
- Remove protective cap from pH electrode and rinse probe with deionized or distilled water
- Pour fresh HI7010-M buffer solution into a clean beaker and immerse electrode, ensuring junction and bulb are fully submerged
- Follow your Hanna meter's calibration protocol to set the 10.01 pH point, allowing readings to stabilize before confirming
- Rinse electrode thoroughly with deionized water after calibration and store according to manufacturer instructions
- Discard used buffer solution after each calibration session to maintain accuracy
Works With
The HI7010-M pH 10.01 buffer solution is compatible with all Hanna Instruments pH meters and electrodes, as well as most third-party pH testing equipment requiring alkaline calibration points. Use this buffer as part of a two-point or three-point calibration alongside pH 4.01 and pH 7.01 buffers for complete range accuracy in water quality testing, aquarium monitoring, hydroponics, and reverse osmosis system management.