Pentair Residential RO Membrane

Pentair TLC Replacement Reverse Osmosis Membrane Element

Thin layer composite membrane engineered for reliable rejection and long shelf life across a wide range of residential water conditions

NSF/ANSI 58 Certified 24 GPD 98% NaCl Rejection
WHY IT WORKS

State-of-the-art filtration for demanding water sources

🧬

Thin Layer Composite Design

Advanced TLC membrane structure delivers consistent high rejection rates even when facing elevated TDS input water

📦

100% Dry Packaging

Factory-sealed dry packaging extends shelf life and ensures membrane integrity until installation

🔧

Standard Dimensions

Built to 1.79" x 11.75" standard sizing for drop-in compatibility with common residential membrane housings

NSF/ANSI 58 Certified

Independently tested and certified to meet rigorous reverse osmosis drinking water treatment system standards

SPECIFICATIONS

Technical Details

Membrane Type Thin Layer Composite (TLC)
Production Rate 24 gallons per day
Dimensions 1.79" diameter × 11.75" length
NaCl Rejection 98% nominal
Certification NSF/ANSI Standard 58
Packaging 100% dry sealed
COMPATIBILITY

Fits standard residential RO systems

The Pentair TLC membrane element is built to industry-standard 1.79" × 11.75" dimensions and fits most residential reverse osmosis systems with compatible membrane housings. Suitable for systems requiring 24 GPD membrane production capacity. Verify your system's membrane specifications before ordering.

MAINTENANCE

Replacement schedule

Every 2-3 Years

RO Membrane Replacement

Replace the Pentair TLC membrane element based on water quality testing or when production rate declines noticeably

Every 6-12 Months

Pre-Filter Cartridges

Replace sediment and carbon pre-filters regularly to protect membrane from fouling and extend service life

Annual

System Sanitization

Sanitize RO system and storage tank when replacing membrane to maintain water quality and system performance

🏆

NSF Certified Quality

Third-party tested to NSF/ANSI 58 for contaminant reduction performance

💧

High TDS Stability

Maintains rejection rates even with challenging high-TDS source water

📏

Universal Fit

Standard dimensions ensure compatibility with most residential RO housings

Extended Shelf Life

Dry packaging allows for long-term storage without performance degradation

Pentair Residential RO Membrane

Pentair TLC Replacement Reverse Osmosis Membrane Element

Thin layer composite membrane engineered for reliable rejection and long shelf life across a wide range of residential water conditions

NSF/ANSI 58 Certified 24 GPD 98% NaCl Rejection
WHY IT WORKS

State-of-the-art filtration for demanding water sources

🧬

Thin Layer Composite Design

Advanced TLC membrane structure delivers consistent high rejection rates even when facing elevated TDS input water

📦

100% Dry Packaging

Factory-sealed dry packaging extends shelf life and ensures membrane integrity until installation

🔧

Standard Dimensions

Built to 1.79" x 11.75" standard sizing for drop-in compatibility with common residential membrane housings

NSF/ANSI 58 Certified

Independently tested and certified to meet rigorous reverse osmosis drinking water treatment system standards

SPECIFICATIONS

Technical Details

Membrane Type Thin Layer Composite (TLC)
Production Rate 24 gallons per day
Dimensions 1.79" diameter × 11.75" length
NaCl Rejection 98% nominal
Certification NSF/ANSI Standard 58
Packaging 100% dry sealed
COMPATIBILITY

Fits standard residential RO systems

The Pentair TLC membrane element is built to industry-standard 1.79" × 11.75" dimensions and fits most residential reverse osmosis systems with compatible membrane housings. Suitable for systems requiring 24 GPD membrane production capacity. Verify your system's membrane specifications before ordering.

MAINTENANCE

Replacement schedule

Every 2-3 Years

RO Membrane Replacement

Replace the Pentair TLC membrane element based on water quality testing or when production rate declines noticeably

Every 6-12 Months

Pre-Filter Cartridges

Replace sediment and carbon pre-filters regularly to protect membrane from fouling and extend service life

Annual

System Sanitization

Sanitize RO system and storage tank when replacing membrane to maintain water quality and system performance

🏆

NSF Certified Quality

Third-party tested to NSF/ANSI 58 for contaminant reduction performance

💧

High TDS Stability

Maintains rejection rates even with challenging high-TDS source water

📏

Universal Fit

Standard dimensions ensure compatibility with most residential RO housings

Extended Shelf Life

Dry packaging allows for long-term storage without performance degradation

Select Production Rate
From $14.62

Original: $41.78

-65%
Pentair (TLC) Replacement Reverse Osmosis Membrane Element

$41.78

$14.62

Description

Pentair Residential RO Membrane

Pentair TLC Replacement Reverse Osmosis Membrane Element

Thin layer composite membrane engineered for reliable rejection and long shelf life across a wide range of residential water conditions

NSF/ANSI 58 Certified 24 GPD 98% NaCl Rejection
WHY IT WORKS

State-of-the-art filtration for demanding water sources

🧬

Thin Layer Composite Design

Advanced TLC membrane structure delivers consistent high rejection rates even when facing elevated TDS input water

📦

100% Dry Packaging

Factory-sealed dry packaging extends shelf life and ensures membrane integrity until installation

🔧

Standard Dimensions

Built to 1.79" x 11.75" standard sizing for drop-in compatibility with common residential membrane housings

NSF/ANSI 58 Certified

Independently tested and certified to meet rigorous reverse osmosis drinking water treatment system standards

SPECIFICATIONS

Technical Details

Membrane Type Thin Layer Composite (TLC)
Production Rate 24 gallons per day
Dimensions 1.79" diameter × 11.75" length
NaCl Rejection 98% nominal
Certification NSF/ANSI Standard 58
Packaging 100% dry sealed
COMPATIBILITY

Fits standard residential RO systems

The Pentair TLC membrane element is built to industry-standard 1.79" × 11.75" dimensions and fits most residential reverse osmosis systems with compatible membrane housings. Suitable for systems requiring 24 GPD membrane production capacity. Verify your system's membrane specifications before ordering.

MAINTENANCE

Replacement schedule

Every 2-3 Years

RO Membrane Replacement

Replace the Pentair TLC membrane element based on water quality testing or when production rate declines noticeably

Every 6-12 Months

Pre-Filter Cartridges

Replace sediment and carbon pre-filters regularly to protect membrane from fouling and extend service life

Annual

System Sanitization

Sanitize RO system and storage tank when replacing membrane to maintain water quality and system performance

🏆

NSF Certified Quality

Third-party tested to NSF/ANSI 58 for contaminant reduction performance

💧

High TDS Stability

Maintains rejection rates even with challenging high-TDS source water

📏

Universal Fit

Standard dimensions ensure compatibility with most residential RO housings

Extended Shelf Life

Dry packaging allows for long-term storage without performance degradation

Pentair (TLC) Replacement Reverse Osmosis Membrane Element | Isopure Water