Pro Products (3506050) "Neutra-7" Acid Water Neutralization Compound 5 lbs
Neutra-7 Technical Details
| Model Number | 3506050 |
| Product Weight | 5 lbs |
| Application | Acid water neutralization and pH elevation |
| Materials | USP and food grade compounds |
| Formulation | Non-caking, rapid-dissolve proprietary blend |
| Feed Method | Chemical feed pump injection systems |
| Pump Compatibility | All major chemical feed pump brands |
| Storage | Keep sealed in cool, dry location |
Mixing and Application Protocol
- Test your water pH to determine the severity of acidity and calculate the required dosage for your flow rate and pH target.
- Mix Neutra-7 compound with clean water in your chemical feed tank according to the mixing instructions printed on the container. The formula dissolves rapidly and stays in solution longer than soda ash alternatives.
- Connect the feed pump suction line to the solution tank and set the injection point upstream of pressure tanks or fixtures to allow adequate contact time.
- Adjust pump feed rate based on water flow and re-test pH downstream after 24 hours of operation. Fine-tune dosage as needed to achieve neutral pH range of 7.0 to 8.0.
System Integration
Neutra-7 works with all major brands of chemical feed pumps and injection systems. The proprietary formulation prevents clogging of pump screens and check valves, a common failure point when using standard soda ash. The compound is designed to prevent scaling at the point of injection, eliminating the localized high pH spikes that cause hard water scale buildup in pipes and fittings. Safe for use in potable water systems with all common plumbing materials including copper, PEX, CPVC, and stainless steel.
Neutra-7 Technical Details
| Model Number | 3506050 |
| Product Weight | 5 lbs |
| Application | Acid water neutralization and pH elevation |
| Materials | USP and food grade compounds |
| Formulation | Non-caking, rapid-dissolve proprietary blend |
| Feed Method | Chemical feed pump injection systems |
| Pump Compatibility | All major chemical feed pump brands |
| Storage | Keep sealed in cool, dry location |
Mixing and Application Protocol
- Test your water pH to determine the severity of acidity and calculate the required dosage for your flow rate and pH target.
- Mix Neutra-7 compound with clean water in your chemical feed tank according to the mixing instructions printed on the container. The formula dissolves rapidly and stays in solution longer than soda ash alternatives.
- Connect the feed pump suction line to the solution tank and set the injection point upstream of pressure tanks or fixtures to allow adequate contact time.
- Adjust pump feed rate based on water flow and re-test pH downstream after 24 hours of operation. Fine-tune dosage as needed to achieve neutral pH range of 7.0 to 8.0.
System Integration
Neutra-7 works with all major brands of chemical feed pumps and injection systems. The proprietary formulation prevents clogging of pump screens and check valves, a common failure point when using standard soda ash. The compound is designed to prevent scaling at the point of injection, eliminating the localized high pH spikes that cause hard water scale buildup in pipes and fittings. Safe for use in potable water systems with all common plumbing materials including copper, PEX, CPVC, and stainless steel.
Original: $13.79
-65%$13.79
$4.83Description
Neutra-7 Technical Details
| Model Number | 3506050 |
| Product Weight | 5 lbs |
| Application | Acid water neutralization and pH elevation |
| Materials | USP and food grade compounds |
| Formulation | Non-caking, rapid-dissolve proprietary blend |
| Feed Method | Chemical feed pump injection systems |
| Pump Compatibility | All major chemical feed pump brands |
| Storage | Keep sealed in cool, dry location |
Mixing and Application Protocol
- Test your water pH to determine the severity of acidity and calculate the required dosage for your flow rate and pH target.
- Mix Neutra-7 compound with clean water in your chemical feed tank according to the mixing instructions printed on the container. The formula dissolves rapidly and stays in solution longer than soda ash alternatives.
- Connect the feed pump suction line to the solution tank and set the injection point upstream of pressure tanks or fixtures to allow adequate contact time.
- Adjust pump feed rate based on water flow and re-test pH downstream after 24 hours of operation. Fine-tune dosage as needed to achieve neutral pH range of 7.0 to 8.0.
System Integration
Neutra-7 works with all major brands of chemical feed pumps and injection systems. The proprietary formulation prevents clogging of pump screens and check valves, a common failure point when using standard soda ash. The compound is designed to prevent scaling at the point of injection, eliminating the localized high pH spikes that cause hard water scale buildup in pipes and fittings. Safe for use in potable water systems with all common plumbing materials including copper, PEX, CPVC, and stainless steel.