R-Can Sterilight (602916) Bolt, Sleeve S80-SV50 TOP

Product image 1

R-Can Sterilight (602916) Bolt, Sleeve S80-SV50 TOP

The R-Can Sterilight 602916 Bolt and Sleeve assembly is a critical replacement component designed specifically for S80-SV50 TOP UV systems. This OEM part ensures proper lamp retention and electrical contact in your ultraviolet disinfection unit.
SPECIFICATIONS

Technical Details

Manufacturer R-Can Environmental (Sterilight)
Part Number 602916
Component Type Bolt and Sleeve Assembly
Compatible Models S80-SV50 TOP UV Systems
Function Lamp Retention & Electrical Contact
Position Top Cap Assembly
Material Metal Assembly with Insulating Sleeve
Replacement Frequency As Needed or During Lamp Changes
INSTALLATION & USE

Replacement Procedure

  1. Disconnect power to the UV system and allow the lamp to cool for at least 15 minutes before beginning work.
  2. Remove the top cap assembly from your S80-SV50 unit and carefully extract the existing bolt and sleeve if replacing a worn component.
  3. Install the new 602916 bolt and sleeve assembly, ensuring the insulating sleeve is properly seated and the bolt makes clean electrical contact with the lamp terminal.
  4. Reassemble the top cap, verify all connections are secure, and restore power to test proper lamp ignition.
COMPATIBILITY

System Requirements

This bolt and sleeve assembly is engineered exclusively for R-Can Sterilight S80-SV50 TOP ultraviolet water disinfection systems. It is not interchangeable with bottom-mount configurations or other UV system models. Always verify your system model before ordering replacement hardware to ensure proper fit and electrical performance.

🔧 Inspect the bolt and sleeve for corrosion or wear during every lamp replacement. A compromised electrical connection can prevent lamp ignition or cause intermittent operation, so replacing this inexpensive component proactively can save hours of troubleshooting down the line.
The R-Can Sterilight 602916 Bolt and Sleeve assembly is a critical replacement component designed specifically for S80-SV50 TOP UV systems. This OEM part ensures proper lamp retention and electrical contact in your ultraviolet disinfection unit.
SPECIFICATIONS

Technical Details

Manufacturer R-Can Environmental (Sterilight)
Part Number 602916
Component Type Bolt and Sleeve Assembly
Compatible Models S80-SV50 TOP UV Systems
Function Lamp Retention & Electrical Contact
Position Top Cap Assembly
Material Metal Assembly with Insulating Sleeve
Replacement Frequency As Needed or During Lamp Changes
INSTALLATION & USE

Replacement Procedure

  1. Disconnect power to the UV system and allow the lamp to cool for at least 15 minutes before beginning work.
  2. Remove the top cap assembly from your S80-SV50 unit and carefully extract the existing bolt and sleeve if replacing a worn component.
  3. Install the new 602916 bolt and sleeve assembly, ensuring the insulating sleeve is properly seated and the bolt makes clean electrical contact with the lamp terminal.
  4. Reassemble the top cap, verify all connections are secure, and restore power to test proper lamp ignition.
COMPATIBILITY

System Requirements

This bolt and sleeve assembly is engineered exclusively for R-Can Sterilight S80-SV50 TOP ultraviolet water disinfection systems. It is not interchangeable with bottom-mount configurations or other UV system models. Always verify your system model before ordering replacement hardware to ensure proper fit and electrical performance.

🔧 Inspect the bolt and sleeve for corrosion or wear during every lamp replacement. A compromised electrical connection can prevent lamp ignition or cause intermittent operation, so replacing this inexpensive component proactively can save hours of troubleshooting down the line.
$12.00
R-Can Sterilight (602916) Bolt, Sleeve S80-SV50 TOP
$12.00

Description

The R-Can Sterilight 602916 Bolt and Sleeve assembly is a critical replacement component designed specifically for S80-SV50 TOP UV systems. This OEM part ensures proper lamp retention and electrical contact in your ultraviolet disinfection unit.
SPECIFICATIONS

Technical Details

Manufacturer R-Can Environmental (Sterilight)
Part Number 602916
Component Type Bolt and Sleeve Assembly
Compatible Models S80-SV50 TOP UV Systems
Function Lamp Retention & Electrical Contact
Position Top Cap Assembly
Material Metal Assembly with Insulating Sleeve
Replacement Frequency As Needed or During Lamp Changes
INSTALLATION & USE

Replacement Procedure

  1. Disconnect power to the UV system and allow the lamp to cool for at least 15 minutes before beginning work.
  2. Remove the top cap assembly from your S80-SV50 unit and carefully extract the existing bolt and sleeve if replacing a worn component.
  3. Install the new 602916 bolt and sleeve assembly, ensuring the insulating sleeve is properly seated and the bolt makes clean electrical contact with the lamp terminal.
  4. Reassemble the top cap, verify all connections are secure, and restore power to test proper lamp ignition.
COMPATIBILITY

System Requirements

This bolt and sleeve assembly is engineered exclusively for R-Can Sterilight S80-SV50 TOP ultraviolet water disinfection systems. It is not interchangeable with bottom-mount configurations or other UV system models. Always verify your system model before ordering replacement hardware to ensure proper fit and electrical performance.

🔧 Inspect the bolt and sleeve for corrosion or wear during every lamp replacement. A compromised electrical connection can prevent lamp ignition or cause intermittent operation, so replacing this inexpensive component proactively can save hours of troubleshooting down the line.
R-Can Sterilight (602916) Bolt, Sleeve S80-SV50 TOP | Isopure Water