Compatible to Intelifil (IF-SM-AA010) 9.75"x2.75" Activated Alumina Fluoride Removal Filter by IPW Industries Inc
Filter Technical Data
| Dimensions | 9.75" x 2.75" |
| Compatible With | Intelifil IF-SM-AA010 |
| Filter Media | Activated Alumina |
| Design Flow Rate | 0.25 GPM |
| Operating Temperature | 40°F to 100°F |
| Filter Capacity | 5,000 mg/L |
| Weight | 2 lbs |
| Applications | RO Systems, Whole House |
Setup & Replacement
- Shut off water supply and relieve system pressure before opening the filter housing
- Remove old cartridge and clean the housing sump with a mild bleach solution, then rinse thoroughly
- Insert the new activated alumina cartridge into the housing and ensure proper seating
- Hand-tighten the housing cap, restore water pressure, and check for leaks
- Flush the system for 3-5 minutes before use to remove any loose media fines
What This Filter Reduces
Activated alumina media is highly effective at reducing fluoride, inorganic arsenic, hydrogen sulfide, hydrogen chloride, carbonyl sulfide, carbon dioxide, alcohols, and ethers from drinking water. This filter is designed for standard 10-inch housings and works as a point-of-use stage in reverse osmosis systems or as a dedicated fluoride reduction cartridge in whole-house applications. EPA guidance suggests fluoride levels above 2 mg/L can cause dental fluorosis, and levels above 4 mg/L may present serious health risks. This cartridge is compatible with Watts, Intelifil, and other standard 10" x 2.5" housings.
Filter Technical Data
| Dimensions | 9.75" x 2.75" |
| Compatible With | Intelifil IF-SM-AA010 |
| Filter Media | Activated Alumina |
| Design Flow Rate | 0.25 GPM |
| Operating Temperature | 40°F to 100°F |
| Filter Capacity | 5,000 mg/L |
| Weight | 2 lbs |
| Applications | RO Systems, Whole House |
Setup & Replacement
- Shut off water supply and relieve system pressure before opening the filter housing
- Remove old cartridge and clean the housing sump with a mild bleach solution, then rinse thoroughly
- Insert the new activated alumina cartridge into the housing and ensure proper seating
- Hand-tighten the housing cap, restore water pressure, and check for leaks
- Flush the system for 3-5 minutes before use to remove any loose media fines
What This Filter Reduces
Activated alumina media is highly effective at reducing fluoride, inorganic arsenic, hydrogen sulfide, hydrogen chloride, carbonyl sulfide, carbon dioxide, alcohols, and ethers from drinking water. This filter is designed for standard 10-inch housings and works as a point-of-use stage in reverse osmosis systems or as a dedicated fluoride reduction cartridge in whole-house applications. EPA guidance suggests fluoride levels above 2 mg/L can cause dental fluorosis, and levels above 4 mg/L may present serious health risks. This cartridge is compatible with Watts, Intelifil, and other standard 10" x 2.5" housings.
Original: $54.12
-65%$54.12
$18.94Description
Filter Technical Data
| Dimensions | 9.75" x 2.75" |
| Compatible With | Intelifil IF-SM-AA010 |
| Filter Media | Activated Alumina |
| Design Flow Rate | 0.25 GPM |
| Operating Temperature | 40°F to 100°F |
| Filter Capacity | 5,000 mg/L |
| Weight | 2 lbs |
| Applications | RO Systems, Whole House |
Setup & Replacement
- Shut off water supply and relieve system pressure before opening the filter housing
- Remove old cartridge and clean the housing sump with a mild bleach solution, then rinse thoroughly
- Insert the new activated alumina cartridge into the housing and ensure proper seating
- Hand-tighten the housing cap, restore water pressure, and check for leaks
- Flush the system for 3-5 minutes before use to remove any loose media fines
What This Filter Reduces
Activated alumina media is highly effective at reducing fluoride, inorganic arsenic, hydrogen sulfide, hydrogen chloride, carbonyl sulfide, carbon dioxide, alcohols, and ethers from drinking water. This filter is designed for standard 10-inch housings and works as a point-of-use stage in reverse osmosis systems or as a dedicated fluoride reduction cartridge in whole-house applications. EPA guidance suggests fluoride levels above 2 mg/L can cause dental fluorosis, and levels above 4 mg/L may present serious health risks. This cartridge is compatible with Watts, Intelifil, and other standard 10" x 2.5" housings.